Abstract
This article describes basic radiation dose concepts as well as those specifically developed to describe the radiation dose from computed tomography (CT). Basic concepts of radiation dose are reviewed, including exposure, absorbed dose, and effective dose. Radiation dose from CT demonstrates variations within the scan plane and along the z axis because of its unique geometry and usage. Several CT-specific dose descriptors have been developed: the Multiple Scan Average Dose descriptor, the Computed Tomography Dose Index (CTDI) and its variations (CTDI(100), CTDI(w), CTDI(vol)), and the dose-length product. Factors that affect radiation dose from CT include the beam energy, tube current-time product, pitch, collimation, patient size, and dose reduction options. Methods of reducing the radiation dose to a patient from CT include reducing the milliampere-seconds value, increasing the pitch, varying the milliampere-seconds value according to patient size, and reducing the beam energy. The effective dose from CT can be estimated by using Monte Carlo methods to simulate CT of a mathematical patient model, by estimating the energy imparted to the body region being scanned, or by using conversion factors for general anatomic regions. Issues related to radiation dose from CT are being addressed by the Society for Pediatric Radiology, the American Association of Physicists in Medicine, the American College of Radiology, and the Center for Devices and Radiological Health of the Food and Drug Administration.
Keywords
Affiliated Institutions
Related Publications
Low-dose CT of the lungs: preliminary observations.
The potential of low-dose computed tomography (CT) of the lungs was critically evaluated in two patients with normal-appearing lungs and 10 patients with a wide diversity of und...
Application of computerized tomography to radiation therapy and surgical planning
Computerized tomography (CT) which permits imaging the internal anatomy in axial cross section, has had a major impact in medicine, primarily in the diagnostic area. The CT scan...
High-speed three-dimensional X-ray computed tomography: The dynamic spatial reconstructor
Most X-ray CT scanners require a few seconds to produce a single two-dimensional (2-D) image of a cross section of the body. The accuracy of full three-dimensional (3-D) images ...
Single-photon emission computed tomography
The subject of singl-photon emission computed tomography (SPECT) is generally reviewed. The basic interaction processes of gamma rays in matter are outlined, and the formation o...
Shape and dimensions of cardiac chambers: importance of CT section thickness and orientation.
Three-dimensional (3D) computed tomography (CT) scan data were used to quantitate the geometry of all heart chambers. The Dynamic Spatial Reconstructor (DSR) was used to scan do...
Publication Info
- Year
- 2002
- Type
- review
- Volume
- 22
- Issue
- 6
- Pages
- 1541-1553
- Citations
- 602
- Access
- Closed
External Links
Social Impact
Social media, news, blog, policy document mentions
Citation Metrics
Cite This
Identifiers
- DOI
- 10.1148/rg.226025128