Abstract
A variable-density k-space sampling method is proposed to reduce aliasing artifacts in MR images. Because most of the energy of an image is concentrated around the k-space center, aliasing artifacts will contain mostly low-frequency components if the k-space is uniformly undersampled. On the other hand, because the outer k-space region contains little energy, undersampling that region will not contribute severe aliasing artifacts. Therefore, a variable-density trajectory may sufficiently sample the central k-space region to reduce low-frequency aliasing artifacts and may undersample the outer k-space region to reduce scan time and to increase resolution. In this paper, the variable-density sampling method was implemented for both spiral imaging and two-dimensional Fourier transform (2DFT) imaging. Simulations, phantom images and in vivo cardiac images show that this method can significantly reduce the total energy of aliasing artifacts. In general, this method can be applied to all types of k-space sampling trajectories.
Keywords
Affiliated Institutions
Related Publications
Sparse MRI: The application of compressed sensing for rapid MR imaging
Abstract The sparsity which is implicit in MR images is exploited to significantly undersample k ‐space. Some MR images such as angiograms are already sparse in the pixel repres...
Single breath‐hold whole‐heart MRA using variable‐density spirals at 3t
Abstract Multislice breath‐held coronary imaging techniques conventionally lack the coverage of free‐breathing 3D acquisitions but use a considerably shorter acquisition window ...
Efficient <i>k</i>‐space sampling by density‐weighted phase‐encoding
Abstract Acquisition‐weighting improves the localization of MRI experiments. An approach to acquisition‐weighting in a purely phase‐encoded experiment is presented that is based...
Undersampled projection reconstruction applied to MR angiography
Undersampled projection reconstruction (PR) is investigated as an alternative method for MRA (MR angiography). In conventional 3D Fourier transform (FT) MRA, resolution in the p...
Rapid MR Imaging with "Compressed Sensing" and Randomly Under-Sampled 3DFT Trajectories
Recently a rapid imaging method was proposed [1] that exploits the fact that sparse or compressible signals, such as MR images, 3D randomly under-sampled Cartesian trajectory ca...
Publication Info
- Year
- 2000
- Type
- article
- Volume
- 43
- Issue
- 3
- Pages
- 452-458
- Citations
- 232
- Access
- Closed
External Links
Social Impact
Social media, news, blog, policy document mentions
Citation Metrics
Cite This
Identifiers
- DOI
- 10.1002/(sici)1522-2594(200003)43:3<452::aid-mrm18>3.0.co;2-b