Abstract
OBJECTIVES: To determine the test‐retest reliability of the distance covered and the steps taken to complete a 6‐minute walk test by peripheral arterial occlusive disease (PAOD) patients with intermittent claudication. To determine the relationship between the total distance and steps covered during the 6‐minute walk test and clinical measures of PAOD severity. DESIGN: Cross‐sectional design. SETTING: The Claude Pepper Older Americans Independence Center at the University of Maryland at Baltimore. PARTICIPANTS: Sixty‐four PAOD patients between the ages of 45 and 88 years (age = 68 ± 7 years, ankle/brachial index (ABI) = .61 ± .19) were recruited from the Vascular Clinic at the Baltimore Veterans Affairs Medical Center and from radio and newspaper advertisements. MEASUREMENTS: Patients were assessed on a 6‐minute walk test and a treadmill graded exercise test. A second 6‐minute walk test was administered approximately 1 week later. Patients also were characterized in regard to blood pressure in the arms and legs, ABI, anthropometry, body composition, and physical activity. RESULTS: The distances walked during the two 6‐minute walk tests were similar (350 ± 78 m vs 360 ± 73 m), resulting in a high reliability coefficient ( R = .94) and a low coefficient of variation (10.4%). The total steps taken during the 6‐minute walk test also were similar (562 ± 113 steps vs 587 ± 107 steps), resulting in a high reliability coefficient ( R = .90) and a low coefficient of variation (11.7%). Furthermore, the 6‐minute walking distance correlated with the distances to onset ( r = .346, P = .007) and with maximal claudication pain ( r = .525, P < .001) during the treadmill test as well as with ABI ( r = .552, P < .001). CONCLUSION: The 6‐minute walk test yields highly reliable measurements, which are related to the functional and hemodynamic severity of PAOD, in patients with intermittent claudication.
Keywords
Affiliated Institutions
Related Publications
The Effect of Cigarette Smoking Status on Six-Minute Walk Distance in Patients with Intermittent Claudication
The purposes of the study were threefold: (1) to compare 6-minute walk performance as a measure of exercise tolerance among three different groups of peripheral arterial occlusi...
Respiratory Rehabilitation, Exercise Capacity and Quality of Life in Chronic Airways Disease in Old Age
Respiratory rehabilitation improves exercise capacity and quality of life in younger patients but is untried in the aged. We aimed to: (a) assess repeatability of the 6-minute w...
Prediction of Mortality and Morbidity With a 6-Minute Walk Test in Patients With Left Ventricular Dysfunction
<h3>Objective.</h3> —To study the potential usefulness of the 6-minute walk test, a self-paced submaximal exercise test, as a prognostic indicator in patients with left ventricu...
Portable oxygen and exercise tolerance in patients with chronic hypoxic cor pulmonale.
Breathing 30% oxygen during exercise alleviated arterial hypoxaemia and reduced minute ventilation in patients with severe chronic bronchitis. A similar level of oxygen (2 or 4 ...
Reproducibility and responsiveness of quality of life assessment and six minute walk test in elderly heart failure patients
Objective To examine the reproducibility and responsiveness to change of a six minute walk test and a quality of life measure in elderly patients with heart failure. Design Long...
Publication Info
- Year
- 1998
- Type
- article
- Volume
- 46
- Issue
- 6
- Pages
- 706-711
- Citations
- 383
- Access
- Closed
External Links
Social Impact
Social media, news, blog, policy document mentions
Citation Metrics
Cite This
Identifiers
- DOI
- 10.1111/j.1532-5415.1998.tb03804.x