Abstract
Abstract Dynamic images of natural objects exhibit significant correlations in k ‐space and time. Thus, it is feasible to acquire only a reduced amount of data and recover the missing portion afterwards. This leads to an improved temporal resolution, or an improved spatial resolution for a given amount of acquisition. Based on this approach, two methods were developed to significantly improve the performance of dynamic imaging, named k‐t BLAST (Broad‐use Linear Acquisition Speed‐up Technique) and k‐t SENSE (SENSitivity Encoding) for use with a single or multiple receiver coils, respectively. Signal correlations were learned from a small set of training data and the missing data were recovered using all available information in a consistent and integral manner. The general theory of k‐t BLAST and k‐t SENSE is applicable to arbitrary k ‐space trajectories, time‐varying coil sensitivities, and under‐ and overdetermined reconstruction problems. Examples from ungated cardiac imaging demonstrate a 4‐fold acceleration (voxel size 2.42 × 2.52 mm 2 , 38.4 fps) with either one or six receiver coils. k‐t BLAST and k‐t SENSE are applicable to many areas, especially those exhibiting quasiperiodic motion, such as imaging of the heart, the lungs, the abdomen, and the brain under periodic stimulation. Magn Reson Med 50:1031–1042, 2003. © 2003 Wiley‐Liss, Inc.
Keywords
Affiliated Institutions
Related Publications
Improved<i>k</i>–<i>t</i>BLAST and<i>k</i>–<i>t</i>SENSE using FOCUSS
The dynamic MR imaging of time-varying objects, such as beating hearts or brain hemodynamics, requires a significant reduction of the data acquisition time without sacrificing s...
Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI
In several applications, MRI is used to monitor the time behavior of the signal in an organ of interest; e.g., signal evolution because of physiological motion, activation, or c...
Highly constrained backprojection for time‐resolved MRI
Abstract Recent work in k‐t BLAST and undersampled projection angiography has emphasized the value of using training data sets obtained during the acquisition of a series of ima...
SENSE: Sensitivity encoding for fast MRI
New theoretical and practical concepts are presented for considerably enhancing the performance of magnetic resonance imaging (MRI) by means of arrays of multiple receiver coils...
Reduced circular field‐of‐view imaging
Abstract A rapid dynamic imaging technique based on polar k ‐space sampling is presented. A gain in temporal resolution is achieved by angular undersampling. A detailed analysis...
Publication Info
- Year
- 2003
- Type
- article
- Volume
- 50
- Issue
- 5
- Pages
- 1031-1042
- Citations
- 790
- Access
- Closed
External Links
Social Impact
Social media, news, blog, policy document mentions
Citation Metrics
Cite This
Identifiers
- DOI
- 10.1002/mrm.10611