Abstract
A "micro-electrospray" ionization source has been developed that markedly increases the sensitivity of the conventional electrospray source. This was achieved by optimization of the source to accommodate nanoliter flow rates from 300 to 800-nL/min spraying directly from a capillary needle that, for the analysis of peptides, contained C18 liquid chromatography packing as an integrated concentration-desalting device. Thus, a total of 1 fmol of methionine enkephalin was desorbed from the capillary column spray needle, loaded as a 10-μL injection of 100-amol/μL solution. The mass spectrum showed the [M + H](+) ion at m/z 574.2 with a signal-to-noise ratio of better than 5:1 from a chromatographic peak with a width of about 12 s. A narrow range (15-u) tandem mass spectrum was obtained for methionine enkephalin from the injection of 500 amol, and a full-scan tandem-mass spectrum was obtained from 50 fmol. For proteins, the average mass measurement accuracy was approximately 100-200 ppm for the injection of 2.5 fmol of apomyoglobin and 20-40 ppm for 200 fmol. Carbonic anhydrase B and bovine serum albumin showed similar mass measurement accuracies.
Keywords
Affiliated Institutions
Related Publications
A tandem quadrupole/time-of-flight mass spectrometer with a matrix-assisted laser desorption/ionization source: design and performance
A matrix-assisted laser desorption/ionization (MALDI) source has been coupled to a tandem quadrupole/time-of-flight (QqTOF) mass spectrometer by means of a collisional damping i...
An Automated Multidimensional Protein Identification Technology for Shotgun Proteomics
We describe an automated method for shotgun proteomics named multidimensional protein identification technology (MudPIT), which combines multidimensional liquid chromatography w...
Method to Correlate Tandem Mass Spectra of Modified Peptides to Amino Acid Sequences in the Protein Database
A method to correlate uninterpreted tandem mass spectra of modified peptides, produced under low-energy (10-50 eV) collision conditions, with amino acid sequences in a protein d...
Subfemtomole MS and MS/MS Peptide Sequence Analysis Using Nano-HPLC Micro-ESI Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
Subfemtomole peptide sequence analysis has been achieved using microcapillary HPLC columns, with integrated nanoelectrospray emitters, coupled directly to a Fourier transform io...
Automatic Identification of Proteins with a MALDI-Quadrupole Ion Trap Mass Spectrometer
A matrix-assisted laser desorption/ionization (MALDI) ion trap mass spectrometer of new design is described. The instrument is based on a commercial Finnegan LCQ ion trap mass s...
Publication Info
- Year
- 1994
- Type
- article
- Volume
- 5
- Issue
- 7
- Pages
- 605-613
- Citations
- 505
- Access
- Closed
External Links
Social Impact
Social media, news, blog, policy document mentions
Citation Metrics
Cite This
Identifiers
- DOI
- 10.1016/1044-0305(94)85001-1
- PMID
- 24221962