Abstract
Several algorithms exist for correcting the nonuniform intensity in magnetic resonance images caused by field inhomogeneities. These algorithms constitute important preprocessing steps for subsequent image analysis tasks. One such algorithm, known as parametric bias field correction (PABIC), has already been implemented in ITK. Another popular algorithm is the nonuniform intensity normalization (N3) approach. A particularly salient advantage of this algorithm is that it does not require a prior tissue model for its application. In addition, the source code for N3 is publicly available at the McConnell Brain Imaging Centre (Montreal Neurological Institute, McGill University) which includes source code and the coordinating set of perl scripts. This submission describes an implementation of the N3 algorithm for the Insight Toolkit given as a single class, viz. itk::N3MRIBiasFieldCorrectionImageFilter. We tried to maintain minimal difference between the publicly available MNI N3 implementation and our ITK im- plementation. The only intentional variation is the substitution of an earlier contribution, i.e. the class itk::BSplineScatteredDataPointSetToImageFilter, for the originally proposed least-squares approach for B-spline fitting used to model the bias field. In addition, we include a more extensive modification to the original N3 algorithm found in the class itk::N4MRIBiasFieldCorrectionImageFilter. The latter algorithm employs a multi-resolution approach, similar to FFD image registration strategies, and has a slightly modified iterative update scheme.
Keywords
Related Publications
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
A novel approach to correcting for intensity nonuniformity in magnetic resonance (MR) data is described that achieves high performance without requiring a model of the tissue cl...
Automated model-based bias field correction of MR images of the brain
We propose a model-based method for fully automated bias field correction of MR brain images. The MR signal is modeled as a realization of a random process with a parametric pro...
Spatial registration and normalization of images
Abstract This paper concerns the spatial and intensity transformations that map one image onto another. We present a general technique that facilitates nonlinear spatial (stereo...
Adaptive segmentation of MRI data
Intensity-based classification of MR images has proven problematic, even when advanced techniques are used. Intrascan and interscan intensity inhomogeneities are a common source...
A comparison of normalization methods for high densityoligonucleotide array data based on variance and bias
Abstract Motivation: When running experiments that involve multiple high density oligonucleotide arrays, it is important to remove sources of variation between arrays of non-bio...
Publication Info
- Year
- 2010
- Type
- article
- Citations
- 92
- Access
- Closed
External Links
Social Impact
Social media, news, blog, policy document mentions
Citation Metrics
Cite This
Identifiers
- DOI
- 10.54294/jculxw