Abstract
Using a modified confocal fluorescence microscope and a CW argon laser, we have measured fluorescence bursts from diffusing single Rh6G molecules that clearly exceed the background intensity. The exact average number of molecules in the observable volume elements was measured directly via the fluorescence intensity autocorrelation function. This allowed us to estimate the probability of finding several molecules simultaneously in the volume element. A tradeoff between the number of detected fluorescence photons and the signal-to-background ratio was observed. In a volume element of 0.24 fl, 4 photoelectrons on average were detected from a molecule of Rh6G with a fluorescence-to-background ratio of 1000, while the volume element of 60 fl yielded on average 100 photoelectrons with a background of 25 counts. In fast single-molecule detection the intersystem crossing into the triplet state plays an important role, affecting the maximum emission rate from the molecule.
Keywords
Affiliated Institutions
Related Publications
Single-molecule fluorescence detection: autocorrelation criterion and experimental realization with phycoerythrin.
A theory for single-molecule fluorescence detection is developed and then used to analyze data from subpicomolar solutions of B-phycoerythrin (PE). The distribution of detected ...
Probing Individual Molecules with Confocal Fluorescence Microscopy
Confocal fluorescence microscopy coupled with a diffraction-limited laser beam and a high-efficiency detection system has been used to study the diffusive movement and emission ...
Alterations of Single Molecule Fluorescence Lifetimes in Near-Field Optical Microscopy
Fluorescence lifetimes of single Rhodamine 6G molecules on silica surfaces were measured with pulsed laser excitation, time-correlated single photon counting, and near-field sca...
Single molecule studies of quantum dot conjugates in a submicrometer fluidic channel
A microfluidic and optical system was created for the detection and analysis of single molecules in solution. Fluidic channels with submicrometer dimensions were used to isolate...
Optimization of high-sensitivity fluorescence detection
We present general expressions for the number of photons emitted by a fluorescent chromophore as a function of the intensity and the duration of illumination. The aim is to find...
Publication Info
- Year
- 1994
- Type
- article
- Volume
- 4
- Issue
- 3
- Pages
- 259-264
- Citations
- 154
- Access
- Closed
External Links
Social Impact
Social media, news, blog, policy document mentions
Citation Metrics
Cite This
Identifiers
- DOI
- 10.1007/bf01878461
- PMID
- 24233458